@thesis{thesis,
author={AGUS MUSTAQIM},
title ={Penyebab terbakarnya magnetic contactor
pada starter panel frest water pump
hydrophore di MT. PERLA},
year={2019},
url={http://repository.pip-semarang.ac.id/1587/},
abstract={Abstraksi- Magnetic contactor adalah peralatan listrik yang bekerja berdasarkan prinsip induksi electromagnetic. Penelitian yang dilakukan untuk mengetahui faktor, dampak dan upaya dari penyebab terbakarnya magnetic contactor pada starter panel frast water pump hydrophore di MT. PERLA.
Metode penelitian termasuk kualitatif, dengan teknik analisa data mengunakan SHEL, kemudian teknik pembahasan mengunakan USG untuk mendapatkan prioritas masalah.
Hasil penelitian dari kategori software kurang teraturnya proses permintaan suku cadang, kategori hardware kondisi bearing shaft pompa yang rusak, kategori environment kelembaban yang berlebih pada magnetic contactor, kategori lifeware keterampilan crew kapal kurang. Dampak yang terjadi kerusakan permesinan bantu yang mendadak, over heat pada elektomotor, meningkatkan laju korosi, serta penanganan masalah yang buruk. Upaya yang dilakukan memperbaruhi data spare part invetory dan melakukan permintaan suku cadang dengan CMMS, melakukan tindakan perawatan yang tidak direncanakan, menjaga kebersihan lingkungan sekitar mesin, dan belajar tentang aspek yang belum diketahui.}
}