@thesis{thesis,
author={Sudiartha I Wayan and Sunaya I Nengah and Winata I Gede Mahatama Randy},
title ={Analisa Energi Tidak Tersalurkan Pemeliharaan Metode Pdkb Berjarak pada Penyulang Bukit Jati},
year={2023},
url={http://repository.pnb.ac.id/10453/},
abstract={Pekerjaan pemeliharaan biasanya dilakukan dengan keadaan tidak bertegangan, namun
cara tersebut menyebabkan kerugian berhentinya kontinuitas pelayanan pendistribusian
tenaga listrik, sedangkan untuk perusahaan listrik menimbulkan kerugian disisi tidak
terjualnya energi listrik. Untuk menangani hal tersebut, PT. PLN (Persero) ULP
Klungkung menggunakan metode Pekerjaan Dalam Keadaan Bertegangan (PDKB) 20
kV pada pekerjaan pemeliharaan jaringan pada penyulang Bukit Jati. penyusunan
Laporan Tugas Akhir ini metode pengambilan data yang dilakukan oleh penulis yakni
metode studi literatur, metode dokumentasi, metode observasi, dan metode wawancara.
Dari hasil analisis yang diperoleh, nilai ENS atau Energi Tidak Tersalurkan yang dapat
diselamatkan dengan menggunakan metode pekerjaan PDKB Berjarak pada pekerjaan
pemeliharaan jaringan SUTM penggantian jumper di penyulang Bukit Jati senilai
471,116 kWh. Metode PDKB Berjarak dapat menyelamatkan nilai SAIDI sebesar
0.09161 Jam/Pelanggan, SAIFI sebesar 0.03053 Kali/Pelanggan. Penggunaan metode
PDKB Berjarak lebih unggul karena dapat menyelamatkan nilai SAIDI 18,7%,
penyelamatan nilai SAIFI 6,93%.}
}