Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
ROHMANDA, NADYA
Bangkit Sitorus, Meyhart Torsna
Simamora, Yoakim
Subject
Teknik Elektro
Datestamp
2022-10-12 02:55:27
Abstract :
Electrostatic precipitator is a technology that removes residual ash from burning before being released into the atmosphere. Ionization process occurs on to flue gas inside electrostatic precipitator which then collected by collecting plate. Flue gas ionization is one thing that affects the efficiency of electrostatic precipitator. The purpose of this research was to understand the effect of overhaul on efficiency calculation of electrostatic precipitator in Banten 3 Lontar OMU Power Plant. This research uses quantitative research methods with descriptive statistical analysis techniques. The data source used are the performance test inspection report data as well as technical data on the unit 2 electrostatic precipitator obtained from HLKI Banten 3 Lontar Power Plant. Data will be analyzed based on the calculation of total efficiency and the inspections in to the electrostatic precipitator which affect on voltage efficiency. Based on the analysis of the data obtained, the total efficiency of electrostatic precipitator and any increase in voltage applied into discharge electrode will increase dust removal of electrostatic precipitator?s efficiency. Based on inspection data of unit 2 electrostatic precipitator of Banten 3 Lontar Power Plant, overhaul tends to results in increasing voltage value from 36.25 kV into 50.06 kV. The value of total efficiency of unit 2 electrostatic precipitator after overhaul is 76%.