RAMA - REPOSITORY
 DETAIL DOCUMENT
ANALISIS SUSUT DAYA PADA PENYULANG ROLEX DAN PENYULANG ORIENT GI SUKARAME PT.PLN (PERSERO) LAMPUNG
Total View This Week0
Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
Prativa, Giof Agy
Handayani, Oktaria
Koerniawan, Tony
Subject
Teknik Elektro 
Datestamp
2022-10-11 07:13:50 
Abstract :
Lampung is one of the areas with high Plosses, the incidence of power losses is dominated by the distribution network, therefore it is necessary to analyze the calculation of the power losses that occur. The power loss analysis in this study was carried out at the Rolex feeder and the Orient GI Sukarame with the same channel length, namely 15 km. The power loss analysis was carried out by calculating the feeder power loss value at 07.00 and 19.00 which was carried out during January 2020. The average power loss values of the two feeders were as follows:% Plosses of Rolex Feeders at 07.00 was 3.31% and at 19.00 was 4.19%, while the% Plosses of Orient Feeder at 07.00 was 5.76% and at 19.00 was 6.59%. To reduce power losses, network optimization is carried out in the form of conducting reconducting, to determine the value of power loss after reconducting, the Orient Feeder data is used at 19.00 WIB as a calculation sample, then calculates the power loss after the reconductor of the conductor, the average percentage of power loss is 4.89%. , this value is relatively smaller than the average value of the percentage of power loss before the conductor reconducting (the average percentage of power loss before reconducting is 6.59%). Thus it can be concluded that the reconducting conductor can reduce the amount of power losses that occur. 
Institution Info

Institut Teknologi Perusahaan Listrik Negara