ANALISIS PERFORMA TRANSFORMATOR TENAGA DITINJAU DARI SUSUT UMUR TRAFO DAN PEMBEBANAN
Total View This Week0
Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
SIMATUPANG, FORTUNA ELENA ELISABETH
Tresya Mauriray, Kartika
Subject
Teknik Elektro 
Datestamp
2022-10-03 03:28:19 
Abstract :
Transformer is a power tool that can change the level of AC voltage by lowering or raising. Transformers work based on the principle of Electromagnetic Induction. Transformer is an important equipment that needs to be maintained and maintained so that the use of life in the transformer can be long. According to the IEEE standard C.57.91 of 1999 the normal life of the transformer is 20.55 years The estimated normal life of the transformer cannot be calculated with certainty due to various factors. Power transformers are designed to operate with an environmental temperature of about 20 0C. of the damage or failure of insulation from transformer oil is caused by changes in temperature or ambient temperature in the oil-immersed power transformer . In the final task research using an unindo brand power transformer with an rated power of 60 MVA that has been operating for approximately 10 years. In the loading data that is given a load of 100%, 90% and 80% can be seen when burdened 100% shrinking its age by 4 with the hotspot temperature of 110.1 0 C obtained the effect of loading on the shrinkage of the transformer age that is " the more the value of loading then shrink the life of a transformer the larger and the higher the environmental temperature the shorter the operational life and the greater also shrink the age of the power transformer. Heating at transformer entanglements can result in insulation becoming damaged and the increase in oil temperature will change the nature and composition of transformer oil. 