Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
ANGGRAINI, KHOLIDYA OKTANA
Hariyanto, Agung
Subject
Teknik Elektro
Datestamp
2022-09-28 08:18:29
Abstract :
PT. Trafindo Prima Perkasa is an industrial company with electricity tariff class I3 where in this company has a lot of inductive load in the form of electrical machines that generate reactive power that causes power factor value far from the standards set by PT. PLN (Persero). If the power factor value is less than 0.85 then PT. Trafindo Prima perkasa will be given a penalty for excess reactive power. To solve the problem, the value of power factor (PF) must be improved by installing capacitors. The installation of capacitors is able to reduce the value of kVAR so that no fines or penalties for excess kVARh must be paid and can save electricity costs. To increase the power factor of PT customers. Trafindo Prima Perkasa from 0.68 to 0.95 capacitors with a capacity of 44.22 kVAR or when rounded to 50 kVAR using delta circuit