DETAIL DOCUMENT
“ANALISIS KELUARAN BERKAS RADIASI SINAR-X PADA PESAWAT LINEAR ACCELERATOR (LINAC) BERDASARKAN TRS 398 IAEA DI RSUD ARIFIN ACHMAD PROVINSI RIAU”.
Total View This Week0
Institusion
Universitas Jambi
Author
Cahyaningtyas, Saphira Indah
Subject
L Education (General) 
Datestamp
2024-01-11 06:40:40 
Abstract :
RINGKASAN Telah dilakukan penelitian tentang analisis keluaran berkas radiasi sinar-X pada pesawat Linear Accelerator (Linac). Analisis ini bertujuan untuk mengetahui keluaran berkas radiasi pada pesawat Linac menunjukkan nilai 1 cGy atau sama dengan 1 MU, yang diperoleh dari analisis ionisasi chamber, suhu, tekanan, efek polaritas, dan rekombinasi ion. Penelitian ini dilakukan menggunakan energi foton sebesar 6 MV dan energi elektron dengan variasi 4 MeV, 6 MeV, 8 MeV, 10 MeV, 12 MeV, dan 15 MeV. Luas lapangan yang digunakan yaitu 10 cm x 10 cm serta source to surface distance (SSD) 100 cm. Hasil analisis menunjukkan berkas energi foton 6 MV didapatkan nilai keluaran per 1 MU sebesar 1,0046 cGy/MU dengan deviasi 0,46%. Sedangkan pada berkas elektron energi 4 MeV sebesar 1,0112 cGy/MU dengan deviasi 1,12%, energi 6 MeV sebesar 1,0064 cGy/MU dengan deviasi 0,64%, energi 8 MeV sebesar 0,9991 cGy/MU dengan deviasi 0,09%, energi 10 MeV sebesar 0,9987 cGy/MU dengan deviasi 0,13%, energi 12 MeV sebesar 0,9978 cGy/MU dengan deviasi 0,22% dan energi 15 MeV sebesar 1,0013 cGy/MU dengan deviasi 0,13%. Dalam hal ini keluaran berkas radiasi sinar-X pada pesawat Linear Accelerator (Linac) di RSUD Arifin Achmad Provinsi Riau telah sesuai dengan standar TRS 398 IAEA dengan rentang deviasi pengukuran yaitu ±3%. SUMMARY Research has been carried out on analyzing X-ray radiation beam output on a Linear Accelerator (Linac). This research aims to determine the output of the radiation beam on the Linac showing a value of 1 cGy or the same as 1 MU, obtained from analysis of chamber ionization, temperature, pressure, polarity effects, and ion recombination. This research was carried out using a photon energy of 6 MV and electron energies with variations of 4 MeV, 6 MeV, 8 MeV, 10 MeV, 12 MeV, and 15 MeV. The area of the field used is 10 cm x 10 cm and the source to surface distance (SSD) is 100 cm. The analysis results show that the 6 MV photon energy beam produces an output value per 1 MU of 1,0046 cGy/MU with a deviation of 0,46%. Meanwhile, in the 4 MeV electron beam, the energy is 1,0112 cGy/MU with a deviation of 1,12%, the 6 MeV energy is 1,0064 cGy/MU with a deviation of 0,64%, the 8 MeV energy is 0,9991 cGy/MU with a deviation. 0,09%, 10 MeV energy of 0,9987 cGy/MU with a deviation of 0,13%, 12 MeV energy of 0,9978 with a deviation of 0,22%, and 15 MeV energy of 1,0013 cGy/MU with a deviation of 0,13%. In this case, the output of the X-ray radiation beam on the Linear Accelerator (Linac) at Arifin Achmad Regional Hospital, Riau Province is in accordance with the IAEA TRS 398 standard with a measurement deviation range of ±3%. 
Institution Info

Universitas Jambi