Pengaruh Overhaul Terhadap Penurunan Vibrasi Pada Vacuum Pump Unit 4B PLTU UPK Asam-asam
Total View This Week0
Institusion
Institut Teknologi Perusahaan Listrik Negara
Author
Ismail, Ismail
Sulistiyo, Eko
Subject
Teknik Mesin 
Datestamp
2022-09-30 02:33:56 
Abstract :
The vacuum pump at the PLTU is to vacuum the condenser which aims to remove gas molecules from a closed room to an outside area in order to achieve a vacuum pressure, the unit 4 vacuum pump at PLTU UPK Asam-asam experiences high vibrations where the vibration is 5.50 mm/s and has entered in the category D (danger) zone, after inspection the vacuum pump experienced unbalance and several other components were damaged such as bearings and shaft sleeves. After balancing by a third party, replacing the bearing and shaft sleeve, the vibration decreased by 4.47 mm/s but is still in zone D, therefore the vacuum pump must be analyzed further to get to the root of the problem. 

File :
TA ISMAIL.pdf
Institution Info

Institut Teknologi Perusahaan Listrik Negara